Technical Report No. 41, Revised 2022 (TR 41) Virus Filtration
Report / Survey by Parenteral Drug Association, 07/12/2022

Document Format: PDF

Description

TR-41 provides a framework of the principles of operation, types of configuration, and materials of construction of virus-retentive filters and presents best practices for their design, operation, and validation in various applications; key literature references are noted. A QbD approach to virus safety assurance is described that starts with identification of critical process parameters related to virus filtration and discusses design space and operation within the proven acceptable range and normal acceptable range. Challenges to specific applications, such as large and small virus-retentive filters used for downstream processing of biopharmaceuticals, ATMPs, and plasma-derived products, as barrier technology prior to mammalian bioreactor cell culture, or for treating growth media for production of ATMPs, are also addressed. Additional sections examine critical considerations for evaluation and virus clearance validation studies, integrity testing, and sterilization. The final section focuses on future manufacturing technologies under development, such as the integration of virus filtration into continuous bioprocessing applications. Appendix I (Section 12.0) provides additional information-risk evaluation and risk-ranking tools, including a model failure mode and effects analysis (FMEA)-that can be used prior to implementing virus filtration. Appendix II provides an overview and background for evaluating virus filters, and procedures for preparing and enumerating bacteriophage. Detailed, product-specific protocols for filtration and use or recommendation of specific filters over others are out of scope for this document. Manufacturing operational and process topics (e.g., manual vs. automated operation, pressure vs. pump) are also not discussed and should be assessed on an individual basis.

Product Details

Published:
07/12/2022
ISBN(s):
9781945584343
Number of Pages:
60
File Size:
1 file , 1.6 MB

PDA TR 41 PDF

$195.00

Technical Report No. 41, Revised 2008 (TR 41) Virus Filtration
Report / Survey by Parenteral Drug Association, 11/01/2008

Document Format: PDF

Description

This technical report addresses virus removal filters that retain viruses by a size exclusion mechanism. It explains how they work, recommends how to elect the best filter for various applications, physical and biological characterization and test methods, and validation. The 2008 revision expands the original report to cover best practices for filter qualification and validation of filters designed to remove viruses 20 nm in diameter and larger.

Product Details

Published:
11/01/2008
ISBN(s):
9780939459230
Number of Pages:
62
File Size:
1 file , 940 KB
Product Code(s):
01041