AWWA WQTC62365 PDF

$14.00

Comparison Studies on Analysis of Perchlorate in Water by IC/CD and LC/ESI/MS/MS
Conference Proceeding by American Water Works Association, 11/01/2005

Document Format: PDF

Description

This work studied a number of selected difficult water sample matrices. Perchlorate inthese samples, and fortified samples, were analyzed by using three different methods,which include US ENvironmental Protection Agency Methods 314.0 and 331.0 and an in-house reversed-phaseLC/ESI/MS/MS method. The research addressed the following issues: comparabilityof the analytical results provided by these methods; method detection limits (MDLs)and practical minimum reporting levels (MRLs); accuracy and precision;effectiveness of sample pretreatment with cartridges used to reduce matrix effects; and,cost analysis. The results were expected to be helpful for the selection of analyticalmethods for perchlorate monitoring under the UCMR 2. Includes 12 references, tables.

Product Details

Edition:
Vol. – No.
Published:
11/01/2005
Number of Pages:
6
File Size:
1 file , 170 KB
Note:
This product is unavailable in Ukraine, Russia, Belarus