ASTM D7575-11 PDF

$41.00

Standard Test Method for Solvent-Free Membrane Recoverable Oil and Grease by Infrared Determination
standard by ASTM International, 11/01/2011

Document Format: PDF

Description

1.1 This test method covers the determination of oil and grease in produced and waste water samples over the concentration range outlined in Table 1 that can be extracted with an infrared-amenable membrane and measured by infrared transmission through the membrane.

1.2 This method defines oil and grease in water as that which is extractable in the test method and measured by infrared transmission.

1.3 The method detection limit (MDL) and recommended reporting range are listed in Table 1.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

TABLE 1 MDL and Reporting Range

Analyte MDLA (mg/L) Reporting RangeA (mg/L)
Oil and Grease 1.0 5200

A MDL and recommended reporting range determined by Section 12.4, which follows the Code of Federal Regulations, 40 CFR Part 136, Appendix B; limits should be determined by each operator.

Product Details

Published:
11/01/2011
Number of Pages:
12
File Size:
1 file , 430 KB
Redline File Size:
2 files , 820 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus