ASTM C1057-17 PDF

$38.00

Standard Practice for Determination of Skin Contact Temperature from Heated Surfaces Using a Mathematical Model and Thermesthesiometer
standard by ASTM International, 05/01/2017

Document Format: PDF

Description

1.1 This practice covers a procedure for evaluating the skin contact temperature for heated surfaces. Two complimentary procedures are presented. The first is a purely mathematical approximation that can be used during design or for worst case evaluation. The second method describes the thermesthesiometer, an instrument that analogues the human sensory mechanism and can be used only on operating systems.

Note 1: Both procedures listed herein are intended for use with Guide C1055. When used in conjunction with that guide, these procedures can determine the burn hazard potential for a heated surface.

Product Details

Published:
05/01/2017
Number of Pages:
7
File Size:
1 file , 200 KB
Redline File Size:
2 files , 470 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus